Everything for your A/C machine: parts, oil & filters
Find your part
Select your machine to find matching parts
Parts by type
Browse through the different parts for Airco & Maintenance

Filters
Keep your air conditioning service equipment running smoothly with our specialized filters for airco machines. These filters are designed to protect your machine from contaminants, such as oil, moisture, and debris, ensuring precise and efficient operation during refrigerant recovery, recycling, and recharging. Regular replacement of machine filters not only extends the lifespan of your equipment but also enhances the accuracy and reliability of airco servicing. Explore our selection of high-quality filters to maintain your airco machines in optimal condition and deliver professional results every time.
View 20 parts
Hoses & accessories
Ensure seamless operation of your air conditioning system with our premium hoses and accessories. Designed for durability and reliability, our hoses facilitate efficient refrigerant flow and connect essential components in your airco system. Alongside hoses, we offer a variety of accessories, including fittings, adapters, and clamps, to support your air conditioning maintenance and repair needs. Whether you're servicing vehicles or managing HVAC systems, our high-quality hoses and accessories are essential for achieving optimal performance and extending the lifespan of your airco equipment. Explore our range to find the right solutions for your maintenance projects.
View 54 parts
Oil & Additives
Ensure the longevity and performance of your vehicle's air conditioning system with our specialized range of oils and additives. From high-quality PAG and POE oils for optimal lubrication to additives that enhance cooling efficiency and protect against wear, we offer products designed to keep your airco system operating smoothly. Proper use of oils and additives not only prevents costly repairs but also maintains the system's efficiency, providing reliable cooling in any climate. Explore our selection to find the right solutions for professional maintenance and long-lasting performance.
View 89 parts
Service couplers
Service couplers connect your service equipment, hoses or charging station to the service ports of an air conditioning system. This category covers manual quick couplers for both the high-pressure side (HP) and the low-pressure side (LP), with and without an integrated tap. The coupler clicks onto the system's service port and connects on the other end to a 1/4" SAE hose or station. Versions with a tap let you open and close the flow while connecting and disconnecting, so no refrigerant is lost. High-pressure and low-pressure couplers are not interchangeable; always check which side and which refrigerant (R134a or R1234yf) your system uses.
View 10 parts
Oil containers
Keep your A/C service equipment running smoothly with our range of high-quality oil containers. These containers are specifically designed for use in automotive A/C service machines and are essential for storing and dispensing PAG oil, POE oil, and UV dye during maintenance and repair work. Built to be durable and resistant to chemical breakdown, these containers ensure safe storage and accurate supply of oils and additives. Whether you need a replacement container or an additional one for handling different oil types, our selection provides reliable solutions that help prevent cross-contamination and keep your service process efficient.
View 10 parts
Detection equipment
Equipment and tools to find leaks in air conditioning systems. This category covers electronic leak detectors, hydrogen/forming gas detectors, UV lamps, UV leak detection dye and injectors used to trace the source of refrigerant loss. Leak detection is a standard part of air conditioning service: a system that loses refrigerant cools poorly and must be leak-free before it is recharged. Depending on the method, you trace leaks with an electronic detector, with forming gas (hydrogen-nitrogen) or with UV dye combined with a UV lamp. Always check which method and which refrigerant suit your equipment and system.
View 12 parts
Adapters
View 102 parts
A/C service stations
Select an A/C service unit based on the refrigerant used in your workshop. Modern cars use R1234yf, older ones R134a. A machine that handles both gives you flexibility. Tank capacity and pump speed determine cycle time. Ensure the unit evacuates, recycles and recharges automatically. Some units only recover refrigerant, they cannot recharge. You need a full service unit for complete maintenance.
View 6 parts
Work gloves & goggles
You have to choose between two types of work gloves here. One type resists coolant and oil, while the other gives you grip for heavy mechanical tasks. Getting the size right is important, because a loose glove reduces the feel in your fingertips. For goggles, pick a version that fits over your own glasses. That seal keeps splashes and dust out of your eyes during the job.
View 3 parts
Service unit spare parts
You buy service unit spare parts for AC machines. Check the thread pitch and coupling before ordering. 1/2 inch ACME is standard for recovery units, but 1/4 inch flare is also used. Ensure the part works with R134a or R1234yf. A wrong filter or seal causes leaks and downtime. Order hoses and valves that fit your exact unit model.
View 29 parts
Refrigerant & cylinders
Your A/C machine runs on the correct refrigerant. Never mix R134a and R1234yf because that destroys the compressor. Choose the cylinder by weight and type, and check the valve fitting on your recovery tank. Order the right gas for every repair.
View 5 parts
A/C cleaning
Clean the vehicle's A/C system with foam or spray. Foam expands and removes bacteria from the evaporator core. Sprays only reach exposed surfaces. Choose foam when odours persist. Use a lance for the deep core. Check the drain hose for blockages first. Make sure the cleaner fits aluminium.
View 19 parts
Measuring tools
This range holds measuring tools you use daily in the workshop. Pick a 150 mm caliper for brake discs and wheel bearings. Digital versions show readings on a display, analogue ones need no battery. Choose stainless steel for durability and a finish that resists workshop dirt. For digital models, the common battery type is LR44. Store instruments in a case to keep them dry and dust-free. Accurate work starts with a reliable measurement, so select the version that matches your measuring frequency.
View 29 parts
Service sets
First, determine what refrigerant you work with. R134a and R1234yf have different quick couplings. The wrong choice gives leaks. These sets contain gauges, hoses, and connectors. You use them to measure pressure and recharge. A set with a vacuum pump handles a full recovery and refill. Check the connection size of your existing equipment before ordering.
View 26 partsWe supply parts for brands like
Original and compatible parts from all major brands
Most popular parts for Airco & Maintenance
The most ordered parts by our customers

Lubrisen leak stop R134A

Universal dye 1000ML R134A / R1234YF hybrid and electric

Lubrisen universal PAG oil 1000ML

Lubrisen leak stop R134A with UV additive

Lubrisen leak stop R1234YF with UV additive

Lubrisen leak stop R1234YF

POE Lubricant for R134A / R1234YF hybrid and electric 250ML

Universal UV leak detection additive oil 250 ml for R134A / R1234YF / hybrid & electric

R134A tank adapter W21.8 to 14mm for refrigerant cylinder

R1234YF tankadapter 1/2 ACME naar 14mm voor koudemiddelfles
Useful tips for Airco & Maintenance
All articles
R1234yf polymerisation: how to protect your A/C service unit
Polymerisation of R1234yf turns refrigerant into a silicone like solid that can put your A/C service unit out of action. Read what Dometic, Honeywell and Bosch see as the cause and how to protect your equipment with refrigerant identification and the WAECO PolyreactGuard S.
Read more
PAG or POE Oil, and UV Fluid: The right choice for your air conditioning service
Read more
Using leakstop: practical tips for mechanics
Read moreFrequently asked questions about Airco & Maintenance
Answers to the most common questions from our customers
Note the make and model of your charging or recovery station and look at the connection the station needs. Compare that with the top and bottom connection of the adapter, for example M1/4" SAE male on top and M1/8" NPT male underneath. An R-1234yf station asks for different couplings than an R-134a station. Also measure the old adapter, so you know the sizes are right.
A refillable oil bottle you fill yourself with oil from a larger pack, a cartridge replacement goes into the service station in place of the original cartridge. Check on your station which connection the oil line has and whether a cartridge or a bottle goes in. There is also a conversion kit to move from cartridge to bottle. Order the bottle and the oil as two separate lines.
For modern A/C systems with R-1234yf and for hybrid and electric vehicles POE oil is used, for R-134a systems PAG oil. Which of the two you need is in the vehicle data or on the system itself. Never just use the oil that is still on the shelf, because the wrong oil can damage the compressor. The oil and additives are under Oil & additives.
There are two routes. UV leak detection additive goes into the system and belongs with the UV lamp and the protective UV glasses. The electronic hydrogen leak detector is a portable unit you carry along pipes and couplings. Check which method your workshop already uses, so you are not working with two systems side by side. Both are under Detection equipment.
PED 2014/68/EU is the directive for pressure equipment and applies to cylinders with refrigerant under pressure. On the cylinder it states which category it falls under, for example art. 4 par. 3. When you order, watch the connection your service station expects, because R-134a and R-1234yf have different couplings. Keep those two apart on the shelf and use the right cylinder adapter.
A/C service: choose by connection and machine
Which connection do you need
With an adapter or service coupling you look first at the two ends of the part. The top is for example M1/4" SAE male with a conical flare, the bottom M1/8" NPT male with a tapered pipe thread. An R-134a high pressure quick coupling carries the marking HP, a low pressure quick coupling LP. Write both ends down before you order, because an adapter with the right top and the wrong bottom will not fit. In Adapters Adapters the versions sit side by side, with the connection of each one in the specifications.
For which service station
Adapters and service couplings are made for A/C charging and recovery stations from Robinair, Ecotechnics, Air Solutions, Oksys, Texa, Brain Bee, Mahle and Bosch, among others. Give the make and model of your station when you search, and the choice stays limited to the versions that fit it. For R-1234yf systems there are separate couplings, which do not belong on an R-134a station. The service couplings themselves are in Service couplers Service couplings.
Changing oil: bottle or cartridge
When you change compressor oil you work with a refillable oil bottle or with a cartridge replacement. The bottles come in several capacities, including 250 ml, and there is a conversion kit to move from cartridge to bottle. Check on your service station which connection the oil line has and whether a cartridge or a bottle goes in. The oil itself, PAG and POE, is under Oil & Additives Oil & additives. Order the bottle and the oil as two separate lines.
Leak detection: additive or detector
There are two routes for tracing a leak. UV leak detection additive goes into the system and belongs with the UV lamp and the protective UV glasses. The electronic hydrogen leak detector is a portable unit you carry along pipes and couplings. Both are in Detection equipment Detection equipment, together with the matching glasses and lamps. Before you order, check which method your workshop already uses, so you are not working with two systems side by side.
Filters and hoses
Filters and filter driers belong to the service interval and take up moisture in the circuit. Hoses and accessories come in various diameters and lengths, with connections for the most used charging and recovery stations. Measure the old hose or filter before you order.
Refrigerant and cylinders
Refrigerant and cylinders sit apart, with the cylinder adapters that connect 1/4" SAE service equipment to a refrigerant cylinder. Watch the PED 2014/68/EU marking on the cylinder and the connection your station expects. R-134a and R-1234yf have different couplings, so keep those two apart on the shelf. The cylinders and accessories are in Refrigerant & cylinders Refrigerant & cylinders.